9104
Plasma/Oxy Fuel Default IO & Setup
Plasma
Torch On: Spindle CW Output (default - Output1) [Torch interface board]
Arc OK: THC On [Torch interface board]
Raise/Lower: Output4 (For non THC systems)
Plate Marker / Scribe: Output6 [Y3]
Laser Ref: Output12 [Victory OEM]
Oxy Torch
Cut: Output2 [Y1]
PreHeat: Flood Output (default - Output3) [Y0]
Blower: Output10 [Y7]
Setup
Torque input (on Z): X3 (using pin 21 on control cable) (input jumper must be in upper position)
Teco drive parameters (w/ torque input):
- Cn011 = -30
- Cn010 = 30
- Tn108 = 22
- Hn517 = 8
Macros used:
- M6start - used to set offsets for plate marker or drill
- M418 - initialization macro for setup
- M419 - added to initialization string
- M460/461 - torch on/off for plasma/oxy
- M430 - drill cycle
- M435/436 - plate marker macro
Tool Number Setup (Marker Offsets / Tool Selector):
- Torch: T1-99
- Drill: T100-249
- Marker / Scriber: T250+ = M6Start.M1S to change offset