9104

Plasma/Oxy Fuel Default IO & Setup

Plasma

Torch On: Spindle CW Output (default - Output1) [Torch interface board]

Arc OK: THC On [Torch interface board]

Raise/Lower: Output4 (For non THC systems)

Plate Marker / Scribe: Output6 [Y3]

Laser Ref: Output12 [Victory OEM]

Oxy Torch

Cut: Output2 [Y1]

PreHeat: Flood Output (default - Output3) [Y0]

Blower: Output10 [Y7]

Setup

Torque input (on Z): X3 (using pin 21 on control cable) (input jumper must be in upper position)

Teco drive parameters (w/ torque input):

  • Cn011 = -30
  • Cn010 = 30
  • Tn108 = 22
  • Hn517 = 8

Macros used:

  • M6start - used to set offsets for plate marker or drill
  • M418 - initialization macro for setup
  • M419 - added to initialization string
  • M460/461 - torch on/off for plasma/oxy
  • M430 - drill cycle
  • M435/436 - plate marker macro

Tool Number Setup (Marker Offsets / Tool Selector):

  • Torch: T1-99
  • Drill: T100-249
  • Marker / Scriber: T250+ = M6Start.M1S to change offset