7654

Latest Plugin and Firmware Versions and Update Instructions (Mach3)

HiCON

Plugin: 1.36.6

Firmware: 2.42

FPGA: 8ACE

DSPMC

Plugin: 4.0.19

Firmware: 8.24

FPGA: E104

PoKeys

Plugin: 1.0.0.1

For the Interpreter 1000

Below are the steps that you would need to follow using the
VSI Device Manager:
_____________________________________________________________________________

  1. Close Mach3 or any application that communicates with the DSPMC.
    Also stop all dspMacros (if there are any).
    _____________________________________________________________________________

  2. Program the new firmware version 8.00 (or greater) to the DSPMC and wait for it to complete. If any error, retry programming without power cycle. Once success go to next step.
    _____________________________________________________________________________

  3. CYCLE THE POWER ON YOUR DSPMC (unplug the power for 5 seconds). Using Soft-Reboot may not be reliable in
    this situation, and could brick your unit.
    _____________________________________________________________________________

  4. Program FPGA version E104. Use the "FPGA Slow Prog" button at the bottom
    of the window. The DSPMC CPU LED will blink rapidly for the programming
    process. Wait for the process to finish (the CPU LED should be in slow
    blink indicating that it is currently in normal operation mode).
    _____________________________________________________________________________

  5. Update your plugin in the Mach3 plugins folder.
    _____________________________________________________________________________

NOTE: Check your plugin config. Depending on your last plugin version, the encoder
and I/O polarity may be reversed by this new update, so you may need to reconfigure
them in mach3.

Also check the Control Output in the DSPMC plugin for each axis (should be DAC) as they may be switched to something
else if updating from a very old plugin version.

results matching ""